Transcranial direct-current stimulation (tDCS)

technology · Secular / clinical-experimental

Transcranial direct-current stimulation (tDCS) is a neurotechnological practice developed by Priori and colleagues in 1998 and parametrically characterized by Nitsche and Paulus in 2000. It is the most extensively studied form of non-invasive electrical brain stimulation. It alters cortical function primarily through weak direct current applied via scalp electrodes — sustained subthreshold polarization that shifts neuronal membrane resting potentials.

The participant sits or reclines while two saline-soaked sponge electrodes are placed against the scalp, typically over the dorsolateral prefrontal cortex or primary motor cortex using the 10–20 EEG positioning system. A constant current of 1 to 2 milliamps is delivered for 20 to 30 minutes per session. The current is ramped up gradually at the start and ramped down at the end to minimize transient sensation.

A typical session lasts 20 to 30 minutes. Sensation is limited to mild tingling, itching, or warmth under the electrodes, usually fading within the first minute as the skin habituates. There is no acute perceptual or cognitive alteration during stimulation comparable to a drug effect; subjective experience is largely indistinguishable from sham. Behavioral and clinical effects emerge across multi-session protocols rather than within a single session.

Adverse effects are generally mild and transient: scalp tingling, itching, headache, and occasional skin redness; serious adverse events have not been documented within standard parameters across more than 33,200 sessions reviewed.[1] Cranial metal implants, cardiac pacemakers, active seizure disorder, and bipolar disorder are contraindications. tDCS is the most extensively studied non-invasive brain stimulation modality and received its first FDA premarket approval for home use in major depressive disorder in December 2025.[2]

History & Tradition

Origins

Applying electrical current to the human head has a documented history extending to the early 1800s, when Giovanni Aldini conducted galvanic experiments on the skull, and to German investigators in the 1870s and 1880s who applied polarizing currents transcranially. The immediate modern precursor is the work of Lippold and Redfearn in 1964, who showed that low-amplitude direct current applied through scalp electrodes altered spontaneous neuronal firing and mood-related behavior in healthy volunteers.[3]

Contemporary tDCS was re-established by two near-simultaneous groups at the end of the 1990s. Priori and colleagues published the first modern demonstration that weak direct current (0.5 mA) delivered through scalp electrodes modulated motor cortex excitability in humans, measured by transcranial magnetic stimulation.[4] Nitsche and Paulus then published the parametric study that established the field's core rules: anodal stimulation increased motor cortex excitability by up to 40%, while cathodal stimulation decreased it, with effects persisting for minutes after stimulation ended.[5] A follow-up paper showed that 9–13 minutes of stimulation produced aftereffects lasting up to 90 minutes, establishing tDCS as a tool for inducing durable neuroplastic change.[6]

Expansion and clinical adoption

Through the 2000s, the Göttingen group led by Nitsche and Paulus characterized the mechanism pharmacologically, showing that aftereffects depend on NMDA receptor activation rather than persistent membrane polarization.[7] During the 2010s, active research programs emerged in São Paulo (Brunoni), New York (Bikson), and Sydney (Loo), expanding applications from the original motor cortex focus into major depressive disorder, stroke rehabilitation, chronic pain, substance use disorders, and aphasia.

A parallel consumer market grew alongside the academic literature, driven by online communities promoting self-administered tDCS for cognitive enhancement. In 2015 the International Federation of Clinical Neurophysiology issued a formal position opposing unregulated home use, citing the absence of established safety and efficacy data outside clinical settings.[8]

Contemporary context

On December 8, 2025 the FDA granted premarket approval to Flow Neuroscience's FL-100, the first prescription at-home tDCS device approved for moderate-to-severe major depressive disorder — the first FDA premarket approval for any home-use non-invasive brain stimulation device.[2] US commercial availability is projected for Q2 2026 at an estimated retail price of $500–$800, with use indicated as monotherapy or adjunctive treatment.[9] The approval marks the consolidation of tDCS into mainstream clinical medicine for one specific indication, alongside a still-active unregulated consumer market.

The Practice

Technique

The participant is seated or reclined in a quiet room. Two electrodes — typically 25–35 cm² rubber pads inside saline-soaked sponge pockets — are positioned on the scalp using the 10–20 EEG system as a landmark reference. The skin under each electrode is inspected for breaks or irritation; long hair is parted to maximize sponge-to-scalp contact. Loose elastic straps hold the electrodes in place. No sedation or fasting is required.

The core method is delivery of a constant low-amplitude direct current through the two scalp electrodes for a fixed duration. Current intensity is 1 to 2 milliamps; session duration is 20 to 30 minutes; the current is ramped up over roughly 30 seconds at the start and ramped down at the end to minimize transient skin sensation.[10] The polarity-dependent rule established by Nitsche and Paulus governs target selection: an anodal electrode over a target region tends to increase local cortical excitability, while a cathodal electrode tends to decrease it.[5] The most common departure from the method is poor electrode preparation — insufficiently humidified sponges, uneven contact, or hair trapped beneath the electrode — which concentrates current, raises charge density, and is the leading cause of skin irritation and rare burns.[1]

Progressive structure

At the introductory tier, a single session uses one validated montage for 10–20 minutes at 1–2 mA, paired with a cognitive task or rest. This single-session design is the basis for most of the field's safety and acute-effect data. At the established tier, sessions are organized into protocol-based clinical series of 10–30 sessions over 2–6 weeks, typically once daily on weekdays. The FDA-approved Flow Neuroscience FL-100 home-use protocol for depression runs over 10 weeks.[2] Dose-response evidence consistently finds that cumulative session count matters more than parameter optimization within a single session; outcomes plateau around 6–10 sessions for some endpoints, and increasing current from 1.5 to 2 mA or extending duration from 20 to 30 minutes does not reliably improve results.

Variations and lineages

The two electrode placements that dominate the literature are anodal left dorsolateral prefrontal cortex (F3) with cathodal right supraorbital, used for depression and cognitive applications, and anodal primary motor cortex (C3 or C4) with cathodal contralateral supraorbital, used for motor rehabilitation and pain. High-Definition tDCS (HD-tDCS) is a research-stage variant using a 4×1 ring array of small gel electrodes in a center-surround configuration to improve spatial focality at the cost of higher per-electrode current density; adverse-event data for HD-tDCS are still emerging.[11] Related modalities — transcranial alternating current stimulation (tACS) and transcranial random noise stimulation (tRNS) — share the broad transcranial electrical stimulation family but differ in waveform and mechanism.

Setting & Preparation

A standard tDCS session requires a quiet, well-lit room and a chair or recliner that supports a stable head position for the full session duration. The participant remains awake; many protocols pair stimulation with a task on a screen, reading, or rest with eyes open.

Equipment falls into three categories. The stimulator delivers constant current at 1–2 mA with ramp-up and ramp-down controls, current-monitoring feedback, and an automatic shutoff if impedance rises sharply (loss of contact). The electrodes are typically rubber pads inside saline-soaked sponge pockets sized 25–35 cm²; saline (NaCl solution) and a measuring syringe ensure consistent sponge wetting. Elastic straps or a stretch headcap hold the electrodes in position. Clinical and research setups add a 10–20 EEG measurement template for placement, skin-preparation supplies (alcohol wipes for impedance reduction), and a session log.[10]

A trained operator is required in research and clinical settings: someone who screens contraindications, prepares the electrodes correctly, monitors for skin irritation, and recognizes when to terminate a session. The Flow Neuroscience FL-100 home device replaces some of this role with hardware safeguards and prescriber oversight, while DIY consumer devices typically provide neither.[12]

Effective tDCS depends on consistent setting and preparation more than on session-to-session variation. The room should be quiet enough for the participant to remain still for 20–30 minutes; bright direct light over the electrodes is unhelpful but ambient room light is fine. The participant should be seated comfortably with the head supported, because head movement can shift electrode contact.

Skin preparation matters. The scalp at each electrode site should be free of cuts, abrasions, eczema, or open lesions; long or thick hair should be parted to maximize sponge-to-scalp contact. Sponges should be uniformly saturated with saline — neither dripping nor under-wetted — because uneven hydration concentrates current and is the leading cause of skin irritation.[10] Validated electrode placement using the 10–20 EEG system (or a manufacturer-provided headcap with fixed positions) is required for reproducible effects; eyeballed placement produces substantial cortical-target error.

Pre-session checks include verifying contraindication status (metal implants, pacemaker, active seizure disorder, bipolar diathesis), reviewing current medications that affect cortical excitability, and confirming that the device displays normal impedance at the start of stimulation.[1]

Guidelines

  • Do not attempt tDCS if you have a cardiac pacemaker, cranial metal implant, cochlear implant, deep brain stimulation electrode, active seizure disorder, or skin lesion at the electrode site.
  • Use only validated parameters: 1–2 mA current, 20–30 minute session duration, 25–35 cm² sponge electrodes, with ramp-up and ramp-down at session start and end.
  • Stop the session immediately if you experience sharp pain, burning that does not fade within the first minute, sudden severe headache, dizziness with nausea, or any sign of seizure aura; do not resume without medical review.
  • Screen for bipolar disorder and recent psychiatric instability before any DLPFC protocol; clinical depression protocols require physician oversight, not self-administration.
  • Limit consecutive daily sessions and inspect the scalp before each new session; rotate placement slightly or rest the skin for a day if irritation appears.
  • Do not combine with alcohol, recreational stimulants, or sedatives in the same session; effects on plasticity and tolerability are altered and the interaction is non-linear.
  • For depression or other clinical indications, use a prescription-grade device under medical supervision (e.g., the FDA-approved FL-100 protocol) rather than a DIY or unregulated consumer device.[2]

Mechanism

Online membrane polarization

During stimulation, the direct current flowing between the two scalp electrodes produces a weak electric field in the underlying cortex. This field shifts the resting membrane potential of pyramidal neurons in the direction of the current: tissue under the anode is depolarized slightly, lowering the firing threshold, while tissue under the cathode is hyperpolarized slightly, raising it. The shifts are subthreshold — tDCS does not directly trigger action potentials. The behavioral consequence in primary motor cortex is the polarity-dependent rule observed since 2000: anodal stimulation increases the amplitude of TMS-evoked motor potentials by up to 40%; cathodal stimulation decreases it.[5]

Aftereffects and NMDA-dependent plasticity

Aftereffects outlasting stimulation by tens of minutes to an hour or more depend on a different mechanism. Pharmacological dissociation studies showed that the NMDA receptor antagonist dextromethorphan abolishes tDCS aftereffects without affecting the online excitability change during stimulation, indicating that aftereffects reflect synaptic LTP- and LTD-analog plasticity rather than continued membrane polarization.[7] Stimulation durations of 9–13 minutes generate aftereffects lasting up to 90 minutes.[6]

Neurochemical modulation

Direct in vivo measurement using 7-Tesla magnetic resonance spectroscopy has shown that both anodal and cathodal tDCS over auditory cortex significantly modulate the GABA-to-glutamate ratio in the stimulated region, with distinct temporal profiles for the two polarities.[13] The catecholaminergic system further gates the magnitude and direction of tDCS-induced plasticity: dopamine and norepinephrine modulators such as methylphenidate can amplify or invert polarity-dependent effects depending on baseline neurochemical state and task context.[14] The polarity-dependent rule, well-replicated for motor cortex with short single sessions, is not absolute: prolonged sessions, non-motor targets, and high-current protocols can produce paradoxical reversals.

Subjective Effects

The subjective experience of tDCS during stimulation is minimal. Most participants report mild tingling, itching, or warmth under one or both electrodes during the first minute, fading as the skin habituates; a smaller fraction report a brief metallic taste or transient phosphenes (visual flashes) at current onset or offset. There is no acute perceptual, emotional, or cognitive alteration comparable to a drug-induced altered state — subjective experience during stimulation is largely indistinguishable from sham, which is part of why sham-controlled blinding works in this field.[15]

Behavioral and clinical effects accumulate across sessions rather than appearing within one. In motor cortex protocols, TMS-measured excitability changes are detectable within minutes of a single session and persist up to 90 minutes.[6] In clinical depression protocols, mood improvement emerges over multi-week courses; in stroke rehabilitation, motor improvement accumulates over a session series paired with physical therapy. Cognitive effects in healthy adults — improvements in working memory, attention, or learning speed — have been reported but replicate inconsistently across laboratories and tasks.[16] Unsought experiences include scalp discomfort during stimulation, post-session headache, fatigue, and rare transient mood worsening; in clinical depression protocols, hypomanic switch has been described in vulnerable individuals.

▸Effect Grid
Intensity Level:
introductory

Low-current montage targeting a cortical region.

Perception(1)intensity
Thinking(1)intensity

Safety

Adverse Effects

Adverse effects from tDCS within validated parameters (≤4 mA, ≤40 minutes per session, 25–35 cm² electrodes) are mild and transient. The largest systematic review of adverse-event reporting across 209 studies found scalp itching in 39.3% of active sessions, tingling in 22.2%, headache in 14.8%, scalp discomfort in 10.4%, and burning sensation in 8.7%; rates for the most common effects did not differ significantly between active and sham conditions, complicating attribution.[15] A subsequent safety update covering more than 33,200 sessions in over 1,000 participants reported no serious adverse events or irreversible injury attributable to tDCS within these parameters.[1]

Skin and local effects

Skin burns are rare with properly prepared electrodes but have been documented with poorly humidified sponges, repeated daily sessions without skin rest, and current density exceeding recommended limits. High-Definition tDCS, which delivers higher per-electrode current density through small ring electrodes, requires particular attention to electrode preparation; adverse effects remain generally mild but the safety dataset is smaller than for conventional tDCS.[11]

Neurological and psychiatric effects

No confirmed tDCS-induced seizures within standard parameters have been documented in published trial data.[1] Hypomanic or manic switch has been described in clinical depression case reports, particularly with anodal DLPFC stimulation in patients with bipolar diathesis; pre-treatment psychiatric screening including bipolar history is required in clinical protocols.[17] Post-session fatigue, transient mood worsening, and difficulty concentrating have been reported sporadically without a clear dose-response signal.

Contraindications

Absolute contraindications

Cranial metal implants within or near the stimulation field — cochlear implants, deep brain stimulation electrodes, cranial plates, intracranial aneurysm clips — are absolute contraindications because metal concentrates current density and creates risk of tissue heating or unintended stimulation. Cardiac pacemakers and other implanted electrical medical devices are also absolute contraindications. Active seizure disorder and current or recent skin lesion at the electrode site rule out stimulation.[17]

Relative contraindications and special populations

Bipolar disorder is a relative contraindication for DLPFC anodal protocols given case-report evidence of manic switch; clinical protocols require psychiatric screening before initiation. Medication that lowers seizure threshold (some antidepressants, antipsychotics, stimulants, tramadol, bupropion at high dose) warrants caution. No safety data exist for tDCS in pregnancy; participants are excluded from trials as a precaution. Pediatric use occurs in some research contexts but is not standard clinical practice and requires specific pediatric safety review. Severe headache disorder, recent traumatic brain injury, and active substance intoxication are reasons to defer stimulation.[10]

Substance Interactions

Documented interactions between tDCS and pharmacological agents are characterized in the laboratory as modulators of tDCS-induced plasticity rather than as clinical safety hazards. No published cases of acute adverse events from combined tDCS and recreational substance use were identified in the research literature.

D-cycloserine, an NMDA partial agonist, prolongs tDCS-induced cortical excitability changes for up to 24 hours post-stimulation, with the greatest effect at 100 mg; this is mechanistically coherent with NMDA-dependent aftereffects and is investigated as a therapeutic enhancer rather than a hazard.[18] Catecholaminergic drugs such as methylphenidate, amphetamine, and levodopa can invert, amplify, or shift the polarity of tDCS-induced plasticity depending on dose, baseline state, and task context; the interaction is non-linear and context-dependent rather than uniformly hazardous.[14] Anticonvulsants, benzodiazepines, and barbiturates broadly suppress cortical excitability and reduce or abolish tDCS aftereffects — the clinical implication is reduced efficacy rather than direct harm. Alcohol suppresses NMDA-dependent plasticity preclinically and is expected to reduce tDCS efficacy, though direct clinical safety data are not available.

A separate research stream investigates tDCS as a therapeutic intervention for cocaine, alcohol, nicotine, and cannabis use disorders, primarily through DLPFC-mediated reduction of craving and improvement of executive control;[19] these are therapeutic applications, not interaction risks.

Habituation

tDCS has no documented habituation, tolerance, or compulsive-use profile. Repeated clinical courses of 10–30 sessions show stable adverse-event rates without escalation; longer-term, the FDA-approved depression protocol covers a 10-week course followed by maintenance schedules without evidence of dependency-like patterns.[2] The principal concern in long-term use is cumulative skin irritation from repeated electrode application at the same site; clinical protocols accommodate this by rotating placement slightly within the validated montage or building in skin-rest days. There is no neurochemical reward signature comparable to substance dependence, and the on-stimulation experience is mild enough that no acute reinforcement loop drives compulsive repetition.[1]

If Distress Arises

The participant retains full agency during a tDCS session — there is no impaired consciousness, motor coordination remains intact, and the stimulator can be stopped at any time. The instruction is to remain seated, keep the head reasonably still, and report sensations as they occur.

Mild tingling, itching, or warmth under the electrodes in the first minute is expected and typically fades. If sensation does not diminish, intensifies sharply, or shifts from tingling to focal burning or sharp pain, the session should be terminated immediately and the electrode site inspected. Ramp-down rather than abrupt shutoff reduces the transient sensation at session end on modern devices.

Stop the session for any of the following: a sudden severe headache different from a familiar pattern, visual disturbances beyond the brief phosphenes that some participants notice at current onset, focal weakness or numbness, dizziness with nausea, or any aura suggestive of seizure activity. Skin redness that does not fade within an hour after session end warrants follow-up. Post-session fatigue and mild headache occur in a minority of participants and resolve within hours; persistent mood worsening over a multi-session course is a reason to consult the prescribing clinician.[15]

Recovery & Support

Most tDCS sessions require no specific recovery beyond removing the electrodes, inspecting the scalp, and resting briefly if mild headache or fatigue is present. The skin under each electrode is typically slightly reddened immediately after; this should fade within 30–60 minutes. Persistent redness, blistering, or focal pain at an electrode site warrants medical review and should be documented before any further session.

For participants in clinical protocols, recovery support is built into the prescribing relationship: the supervising clinician monitors mood, adverse effects, and skin condition across the session course and adjusts parameters or pauses treatment if needed. The Flow Neuroscience FL-100 home device pairs the at-home protocol with prescriber-administered remote monitoring rather than fully unsupervised use.[2]

If a session triggers a manic or hypomanic switch (elevated mood, decreased need for sleep, pressured speech, impulsive behavior), the protocol should be stopped and psychiatric review obtained promptly. If a participant in a DIY or consumer setting develops persistent neurological symptoms, mood change, or unexplained scalp injury, a healthcare provider — ideally one familiar with non-invasive brain stimulation — should be consulted, and unregulated devices should be set aside pending evaluation.[8]

Recovery resources, crisis lines, and support pathways → View all

Progression

Progression in tDCS is measured in sessions rather than in skill or attainment. A single session produces measurable but transient cortical excitability changes; clinical effects emerge across multi-session courses, and dose-response data consistently identify cumulative session count as the dominant variable.

A typical clinical course runs 10 to 30 sessions over 2 to 6 weeks, with daily sessions on weekdays. The FDA-approved Flow Neuroscience FL-100 home protocol for depression runs over 10 weeks; pivotal trial data reported 58% remission in the active arm versus sham at the 10-week endpoint.[2] Improvement typically plateaus around 6–10 sessions for some endpoints, with further sessions extending and consolidating rather than amplifying response. Increasing current intensity from 1.5 to 2 mA or extending duration from 20 to 30 minutes does not reliably improve outcomes; the field's parameter envelope is narrower than the dose-response intuition suggests.[10]

Practitioner progression — for clinicians and researchers, not participants — runs from single-montage familiarity (motor cortex or DLPFC, 1–2 mA, 20 minutes) through multi-montage clinical protocols and, for research labs, into High-Definition tDCS arrays and individualized current modeling. No universally recognized practitioner certification exists; training is acquired through university laboratory apprenticeship, manufacturer training programs, and continuing medical education courses.[10]

Evidence Summary

The tDCS evidence base is among the largest for any non-invasive brain stimulation modality, with the strongest support concentrated on major depressive disorder, motor rehabilitation post-stroke, and chronic pain.

For major depressive disorder, the pivotal trial is ELECT-TDCS, a triple-arm, randomized, double-blind, placebo-controlled non-inferiority trial (n=245) comparing tDCS, escitalopram, and sham over 10 weeks. Active tDCS significantly outperformed sham on the MADRS (mean reduction 9.0 vs. 5.8 points); escitalopram outperformed both (mean reduction 11.3). tDCS did not meet the predefined non-inferiority margin against escitalopram (observed difference −2.3 points, margin −2.75).[20] Multiple meta-analyses confirm the antidepressant effect versus sham at small-to-moderate effect sizes.[21][22][23] A 2024 meta-analysis of 12 RCTs (n=371) confirmed the antidepressant effect and found cognitive enhancement effects in MDD inconclusive.[16] A 2025 meta-analysis confirmed that home-delivered tDCS replicates the clinic-based antidepressant effect,[24] and the FDA premarket approval of the FL-100 in December 2025 formalized this into mainstream clinical practice.[2]

For stroke upper-limb motor rehabilitation, a 2025 systematic review and meta-analysis found that tDCS combined with physical therapy produced clinically meaningful improvement, particularly in the subacute phase, supporting a Level B recommendation.[25] Anodal motor-cortex tDCS for chronic neuropathic pain and fibromyalgia is supported at Level B. Substance-use-disorder applications show acute craving reduction at small, variable effect sizes.[19] Cognitive enhancement in healthy adults remains inconsistent across studies and laboratories; proponents claim measurable improvements in working memory and learning, but meta-analytic replication has not been consistent enough to support routine use.

Limitations

Several limitations cut across the tDCS evidence base.

Sham-control quality is unusually high in this field — both anodal and cathodal stimulation produce minimal subjective sensation after the first minute, and well-designed sham protocols (current ramped up and immediately back down) blind both participants and operators effectively. This strengthens internal validity but means real effect sizes are modest: across major depression meta-analyses, effect sizes are small to moderate, and tDCS underperforms standard-dose SSRI pharmacotherapy on primary endpoints in head-to-head comparison.[20]

Individual response variability is large and unexplained. The same montage and current produce robust effects in some participants and little measurable change in others. Skull thickness, cortical anatomy, lesion presence, baseline neurochemistry, and concurrent medication all contribute, but no clinical predictor reliably stratifies responders from non-responders.[10]

Publication bias toward positive findings has been noted in cognitive-enhancement studies in healthy adults, where small single-site studies report effects that meta-analyses with broader inclusion criteria attenuate or fail to replicate.[16] Protocol heterogeneity — different montages, currents, durations, session counts, and concurrent tasks — limits pooled effect-size precision across indications other than depression, where protocols have converged toward DLPFC anodal stimulation at 2 mA for 20–30 minutes per session.

Most safety data come from research settings with trained operators and screened participants. The growth of consumer and DIY tDCS use creates an evidence gap: adverse-event surveillance in unregulated home use is essentially absent, and the IFCN 2015 position formally opposed home use on these grounds.[8] The FDA approval of the FL-100 partially closes this gap for one indication with prescription oversight, but a large unregulated market persists.

references

  1. [1] 
    ^abcdefBikson, M. and Grossman, P. and Thomas, C. and Zannou, A.L. and Jiang, J. and Adnan, T. and Mourdoukoutas, A.P. and Kronberg, G. and Truong, D. and Boggio, P. and Brunoni, A.R. and Charvet, L. and Fregni, F. and Fritsch, B. and Gillick, B. and Hamilton, R.H. and Hampstead, B.M. and Jankord, R. and Kirton, A. and Knotkova, H. and Liebetanz, D. and Liu, A. and Loo, C. and Nitsche, M.A. and Reis, J. and Richardson, J.D. and Rotenberg, A. and Turkeltaub, P.E. and Woods, A.J. (2016) Safety of Transcranial Direct Current Stimulation: Evidence Based Update 2016 — Brain Stimulation doi:10.1016/j.brs.2016.06.004
  2. [2] 
    ^abcdefghBikson, M. and Brunoni, A.R. and George, M.S. (2026) US FDA approves home-delivered tDCS for treating depression — Brain Stimulation doi:10.1016/j.brs.2025.103021
  3. [3] 
    ^Priori, A. (2016) Brief history of transcranial direct current stimulation
  4. [4] 
    ^Priori, A. and Berardelli, A. and Rona, S. and Accornero, N. and Manfredi, M. (1998) Polarization of the human motor cortex through the scalp — NeuroReport doi:10.1097/00001756-199807130-00020
  5. [5] 
    ^abcNitsche, M.A. and Paulus, W. (2000) Excitability changes induced in the human motor cortex by weak transcranial direct current stimulation — The Journal of Physiology doi:10.1111/j.1469-7793.2000.t01-1-00633.x
  6. [6] 
    ^abcNitsche, M.A. and Paulus, W. (2001) Sustained excitability elevations induced by transcranial DC motor cortex stimulation in humans — Neurology doi:10.1212/wnl.57.10.1899